YY-383
|
YY-383S
|
Configuration
|
Externalmaterial
|
Cold-rolledsteelsheet with melamine resin baked-painting
|
Painting color
|
YSCstandardcolor(DIC-G-61)
|
Temperaturerange
|
4°C to 10°C
|
4°C to10°C (dependonsupplywater temp.)
|
Temperaturecoolingtime
|
60 min (from25°Cto4°C)
|
Temperaturecontroller
|
Digitalsetting,digital indication (PID control)
|
Temperaturesensor
|
Pt 100
|
Refrigerator
|
1.5 kw
|
2.25 kw
|
Cooling unit
|
Stainlesssteelpipecooling unit
|
Refrigerant
|
R-407C(ISO140001compliance)
|
Pump
|
Immersiblepump
|
pHmeterandelectrode
|
Coolantconcentrationmeasurement
|
----
|
Float switch
|
Lead-typeliquidsurface switch
|
Pressure gauge
|
Pressuregaugewiththe contact switch
|
Integrationflow-meter
|
Digitaldisplayflowmeter
|
Water inlet
|
12 mmdia.tubeconnector (with hand valve and solenoid valve)
|
Coolantorwateroutlet
|
12 mmdia.tubeconnector
|
Coolantreturninlet
|
40 mm dia.tubeconnector
|
----
|
Drain
|
PVCpipefitting(with hand valve)
|
Main tank
|
PVC, 100 L
|
Filter
|
50 to 100 micronfilter(2Filter)
|
----
|
Chemicaltank(Threetanks)
|
PVC, 40 L (each tank)
|
----
|
Externaldimensions
|
W900×D1200×H1500mm
|
System
|
Type
|
Re-circulation
|
Drain
|
pH control
|
OK
|
None
|
Filter system
|
OK
|
None
|
ControlPanel
|
Pressure gauge
|
Analogpressuregauge with upper limit contact
Pressure range : 0~1.0MPa Accuracy : ±1%
|
Temperaturecontroller
|
Digitalsetting,digital indication (PID control)
|
pHmeterandelectrode
|
Digitalsetting,digital indication
|
System control
|
ControlledbyProgrammable controller (PLC)
|
Timer
|
99hours59min(arbitrarily set)
|
Emergencystopswitch
|
Mushroomtypelockswitch
|
Lamps
|
Alarmlamps(Temperature, pH, Refrigerator, Pump)opening/stoplamps,Signal tower etc.
|
Safety
|
Over current
|
ProtectbyCircuitbreaker
|
pH condition
|
Upperlimitalarmcontact of pH controller with upper-limit contact isconnected,and Lower limit alarm contact of pH controllerwithupper-limitcontact is connected.
|
Refrigerator
|
ProtectbyThermalrelay
|
Pump
|
ProtectbyThermalrelay and Level sensor
|
Hi pressure
|
Bypressuregaugeupper limit contact
|
Tank level low
|
ByTanklevelsensor
|
Shortcircuitbreaker
|
Shortcircuit/overcurrent has occurred, the power supply isturnedoff.
|
RequiredUtility
|
Power supply
|
AC200/220/380V,3-phase50/60Hz,5 KVA
|
AC200/220/380V,3-phase50/60Hz,7 KVA
|
Water supply
|
Fromfacility
|